Show simple item record

dc.contributor.authorLugez, Elodie
dc.contributor.otherQueen's University (Kingston, Ont.). Theses (Queen's University (Kingston, Ont.))en
dc.date2016-03-22 11:20:08.356en
dc.date.accessioned2016-03-22T20:37:13Z
dc.date.available2016-03-22T20:37:13Z
dc.date.issued2016-03-22
dc.identifier.urihttp://hdl.handle.net/1974/14149
dc.descriptionThesis (Ph.D, Computing) -- Queen's University, 2016-03-22 11:20:08.356en
dc.description.abstractElectromagnetic (EM) tracking assistance for ultrasound-guided high-dose-rate (HDR) prostate brachytherapy has recently been introduced in order to enable prompt and uncomplicated reconstruction of catheter paths with respect to the prostate gland. However, EM tracking within a clinical setting is notorious for fluctuating measurement performance. In fact, measurements are prone to errors due to field distortions caused by magnetic and conductive objects and can compromise the outcome of the procedure. Enhancing these measurements is therefore paramount. The objective of this thesis is to enable robust and accurate reconstructions of HDR catheter paths on the ultrasound images of the prostate gland using EM tracking. To achieve this objective, the measurement uncertainty of an electromagnetic system was first characterized in various environments; this characterization enabled us to identify optimum setup configurations and model the measurement uncertainty. Second, we designed and implemented a specialized filtering method for catheter path reconstructions, combining the nonholonomic motion constraints which apply to the EM sensor, with both the position and orientation measurements of the sensor. Finally, ultrasound scan planes were robustly tracked with the help of a simultaneous localization and calibration algorithm; this method allows for dynamic tracking of the ultrasound probe while simultaneously mapping and compensating for the EM field distortions. We experimentally validated the performance of our advanced filter for catheter path reconstructions in a HDR brachytherapy suite; the EM sensor was threaded within paths of various curvatures at several insertion speeds. The simultaneous ultrasound probe tracking and EM field distortion compensation approach was also assessed in the brachytherapy suite. The performances of our approaches were compared to conventional error minimization methods. The advanced methods effectively increased the EM tracking accuracy of catheter paths and ultrasound probes. With the help of our proposed approaches, EM tracking can provide effective assistance for a plurality of clinical applications.en_US
dc.languageenen
dc.language.isoenen_US
dc.relation.ispartofseriesCanadian thesesen
dc.rightsQueen's University's Thesis/Dissertation Non-Exclusive License for Deposit to QSpace and Library and Archives Canadaen
dc.rightsProQuest PhD and Master's Theses International Dissemination Agreementen
dc.rightsIntellectual Property Guidelines at Queen's Universityen
dc.rightsCopying and Preserving Your Thesisen
dc.rightsCreative Commons - Attribution - CC BYen
dc.rightsThis publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.en
dc.subjectElectromagnetic trackingen_US
dc.subjectHigh-dose-rate prostate brachytherapyen_US
dc.titleElectromagnetic tracking in ultrasound-guided high dose rate prostate brachytherapyen_US
dc.typeThesisen_US
dc.description.degreePh.Den
dc.contributor.supervisorAkl, Selimen
dc.contributor.supervisorFichtinger, Gaboren
dc.contributor.departmentComputingen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record