dc.description.abstractThis thesis presents a simple and user friendly method for calibrating a procam system from a single pose of a 2D planar target. The camera intrinsic parameters, projector intrinsic parameters, procam system's extrinsic parameters and the distortion coe cients of the camera are returned using this method. Two sets of experiments were conducted: simulation experiments and real data experiments. The purpose of the simulation experiments were to test which poses of a camera and projector relative to a chessboard produce accurate calibration parameters. Several poses of a chessboard were imaged and used to calibrate a real procam system using the technique presented in this thesis and a Zhang-based method was used as the ground truth. The results of the real data experiments are congruent with the simulation experiments; accurate camera intrinsic parameters are returned when absolute sum of the X-axis and Y-axis rotation of the chessboard relative to the camera is greater than 20 degrees and accurate projector intrinsic parameters when the absolute value of the Y-axis rotation of the chessboard relative to the projector is greater than 10 degrees. When the conditions for valid camera and projector intrinsic parameters are met then accurate extrinsic parameters are returned as well.en
dc.language.isoengen
dc.relation.ispartofseriesCanadian thesesen
dc.rightsQueen's University's Thesis/Dissertation Non-Exclusive License for Deposit to QSpace and Library and Archives Canadaen
dc.rightsProQuest PhD and Master's Theses International Dissemination Agreementen
dc.rightsIntellectual Property Guidelines at Queen's Universityen
dc.rightsCopying and Preserving Your Thesisen
dc.rightsThis publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.en
dc.rightsCC0 1.0 Universal*
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/*
dc.subjectProcamen
dc.subjectcalibrationen
dc.subjectoptimizationen
dc.subjectstereovisionen
dc.subjecthomographyen
dc.titleProCam Calibration using Single Pose of 2D Planar Targeten
dc.typethesisen
dc.description.degreeM.A.Sc.en
dc.contributor.supervisorGreenspan, Michael
dc.contributor.departmentElectrical and Computer Engineeringen
dc.degree.grantorQueen's University at Kingstonen


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Queen's University's Thesis/Dissertation Non-Exclusive License for Deposit to QSpace and Library and Archives Canada
Except where otherwise noted, this item's license is described as Queen's University's Thesis/Dissertation Non-Exclusive License for Deposit to QSpace and Library and Archives Canada