    Improvement of Speckle-Tracked Freehand 3-D Ultrasound Through the Use of Sensor Fusion

    Thumbnail
    View/Open
    Lang_Andrew_R_200910_MASc.pdf (3.278Mb)
    Date
    2009-10-20
    Author
    Lang, Andrew
    Metadata
    Show full item record
    Abstract
    Freehand 3-D ultrasound (US) using a 2-D US probe has the advantage over conventional 3-D probes of being able to collect arbitrary 3-D volumes at a lower cost. Traditionally, generating a volume requires external tracking to record the US probe position. An alternative means of tracking the US probe position is through speckle tracking. Ultrasound imaging has the advantage that the speckle inherent in all images contains relative position information due to the decorrelation of speckle over distance. However, tracking the position of US images using speckle information alone suffers from drifts caused by tissue inconsistencies and overall lack of accuracy.

    This thesis presents two novel methods of improving the accuracy of speckle-tracked 3-D US through the use of sensor fusion. The first method fuses the speckle-tracked US positions with those measured by an electromagnetic (EM) tracker. Measurements are combined using an unscented Kalman filter (UKF). The fusion is able to reduce drift errors as well as to eliminate high-frequency jitter noise from the EM tracker positions. Such fusion produces a smooth and accurate 3-D reconstruction superior to those using the EM tracker alone.

    The second method involves the registration of speckle-tracked 3-D US volumes to preoperative CT volumes. We regard registration combined with speckle tracking as a form of sensor fusion. In this case, speckle tracking is used in the registration to generate an initial position for each US image. To improve the accuracy of the US-to-CT registration, the US volume is registered to the CT volume by creating individual US "sub-volumes", each consisting of a small section of the entire US volume. The registration proceeds from the beginning of the US volume to the end, registering every sub-volume. The work is validated through spine phantoms created from clinical patient CT data as well as an animal study using a lamb cadaver. Using this technique, we are able to successfully register a speckle-tracked US volume to a CT volume with excellent accuracy. As a by-product of accurate registration, any drift from the speckle tracking is eliminated and the freehand 3-D US volume is improved.
    URI for this record
    http://hdl.handle.net/1974/5280
    Collections
    • Queen's Graduate Theses and Dissertations
    • Department of Electrical and Computer Engineering Graduate Theses
    Request an alternative format
    If you require this document in an alternate, accessible format, please contact the Queen's Adaptive Technology Centre

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us
    Theme by 
    Atmire NV
     

     

    Browse

    All of QSpaceCommunities & CollectionsPublished DatesAuthorsTitlesSubjectsTypesThis CollectionPublished DatesAuthorsTitlesSubjectsTypes

    My Account

    LoginRegister

    Statistics

    View Usage StatisticsView Google Analytics Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us
    Theme by 
    Atmire NV