Show simple item record

dc.contributor.authorThompson, Melanieen
dc.date2009-09-28 12:59:27.59
dc.date2009-09-28 19:42:56.873
dc.date2009-09-29 12:14:18.438
dc.date.accessioned2010-04-06T13:48:23Z
dc.date.available2010-04-06T13:48:23Z
dc.date.issued2010-04-06T13:48:23Z
dc.identifier.urihttp://hdl.handle.net/1974/5519
dc.descriptionThesis (Master, Mechanical and Materials Engineering) -- Queen's University, 2009-09-29 12:14:18.438en
dc.description.abstractOsseointegrated transfemoral implants have been introduced as an alternative to conventional, socket-based prostheses for above knee amputees. This method is showing great promise; however, the frequency of device failure is of concern. As a means to understand some of these failures, this study investigates the mechanical behaviour of three osseointegrated transfemoral implant systems; an in-house prototype design and two assemblies comprised of implant-grade parts provided by Integrum AB, Sweden. A series of mechanical tests were administered to evaluate the effects of tightening specifications and connection geometry on the material response, and mechanical behaviour of the assemblies. The tests included torque-elongation measurements, torque to failure tests, and strain analyses during loading. This research was carried out in an attempt to better understand the behaviour of components under loading, in order to optimize the assembly specifications and improve the useful life of the system. The results obtained confirm that the Integrum assemblies exhibit improved performance when tightened to a level beyond the current specified tightening torque of 12 Nm. Increased tightening torque provides an improved connection between components, leading to increased torque retention, decreased peak tensile strain values and a more gradual, primarily compressive distribution of strains throughout the assembly.en
dc.language.isoengen
dc.relation.ispartofseriesCanadian thesesen
dc.rightsThis publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.en
dc.subjectOsseointegrationen
dc.subjectProsthesisen
dc.subjectTightening Torqueen
dc.subjectPreloaden
dc.subjectElongationen
dc.titleMechanical Analysis of Osseointegrated Transfemoral Implant Systemsen
dc.typethesisen
dc.description.restricted-thesisRestricted due to affiliation with commercially produced implant components. Restriction was previously accepted by Janice Deakin, dated September 26th 2009.en
dc.description.degreeM.A.Sc.en
dc.contributor.supervisorMechefske, Chris K.en
dc.contributor.departmentMechanical and Materials Engineeringen
dc.degree.grantorQueen's University at Kingstonen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record