Modelling and Development of Droplet Generation Method for Magnetically Actuated Digital Microfluidics

Loading...
Thumbnail Image

Authors

Hutama, Timothy

Date

Type

thesis

Language

eng

Keyword

Microfluidics , Fluid Dynamics , Analytical Chemistry , Superhydrophboic , Surface Tension

Research Projects

Organizational Units

Journal Issue

Alternative Title

Abstract

Digital microfluidics is useful in miniaturizing different types of biological tests due to an ability to perform multiple operations on a single chip with a single common geometry. However, one of the largest problems in using digital microfluidics has been biofouling during these processes, a phenomenon which is exacerbated when using electric fields for fluid manipulation. Magnetic microfluidics is an alternative actuation mechanism, which does not have this same limitation. However, until recently it has been impossible to create drops, which can also be subsequently moved to perform multiple step analyses. In this thesis, a method for creating drops on superhydrophobic surfaces using magnetic force as the primary actuation mechanism is outlined. Using numerical simulations in Comsol Multiphysics, the method was explored to determine several of the limitations of the system, including the minimum actuatable volume (5 μL). Additionally, the flow within the drops was explored to obtain a better understanding of the experimental results. Experimental validation of the results followed, and it was found that the system showed a 1-to-1 linear change in drop volume relative to expected dispensed volume, verifying the theoretical model. Experimental validation found that the error of the system is constant over any dispensed volume at ±0.5 μL. The method was applied to miniaturize a standard test for hard water determination, a complexometric EDTA titration. The results from a specially designed chip are compared to a titration of a 10 mL volume of the same sample and two were found to be equal within error (100-170 ppm for the chip, 124±2 ppm for the standard method). The water hardness estimate from the chip was further improved upon by image analysis, and the range narrowed to 120±15 ppm, again within the same error as the standard method. Together with the theoretical analysis, this result verifies the practicality of the method for analytical operations. Finally, preliminary work into making the magnetic droplet manipulation method more general was conducted, and it was found to be possible to create chips which utilize any combination of droplet mixing, merging, moving, and splitting.

Description

Citation

Publisher

License

Attribution-NonCommercial-NoDerivs 3.0 United States
Queen's University's Thesis/Dissertation Non-Exclusive License for Deposit to QSpace and Library and Archives Canada
ProQuest PhD and Master's Theses International Dissemination Agreement
Intellectual Property Guidelines at Queen's University
Copying and Preserving Your Thesis
This publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.

Journal

Volume

Issue

PubMed ID

External DOI

ISSN

EISSN