Connections and Fatigue Behaviour of Precast Concrete Insulated Sandwich Panels

Loading...
Thumbnail Image

Authors

Teixeira, Nathan

Date

2015-09-26

Type

thesis

Language

eng

Keyword

fatigue , BFRP , connections , shear connector , model , sandwich panel

Research Projects

Organizational Units

Journal Issue

Alternative Title

Abstract

This study investigates two aspects of precast concrete insulated sandwich wall panels, namely mechanical connections and fatigue behaviour. In the first part, flexural tests were performed on panels with various end support conditions, loading orientations, and reinforcement and shear connector materials. Bolted angle connections were used to simulate practical support conditions, while loads were applied in a manner to simulate windward pressure as well as suction. Panels with steel and basalt fibre-reinforced polymer (BFRP) longitudinal reinforcement were tested and compared. Discrete steel and BFRP shear connectors were also used and evaluated. The bolted angle connections provided partial end fixity, thereby increasing the overall strength and stiffness relative to identical panels simply supported by rollers during testing. In all cases the bolted connections succeeded in developing the full strength of the sandwich panels. Panels with steel reinforcement failed due to rupturing of flexural reinforcement, while a panel with BFRP reinforcement failed due to rupturing of shear connectors and crushing of concrete in one wythe. Panels loaded in the direction of wind pressure achieved higher peak loads than identical panels loaded to simulate suction. An analytical model accounting for material nonlinearity, end support conditions and partial composite action from the shear transfer system was developed. The model accurately predicted flexural stiffness, while the peak load was underestimated in most cases. In the second part of the study, seven fatigue tests were performed on four panels with either steel or BFRP flexural reinforcement and shear connectors. Cyclic bending was conducted at two loading amplitudes: a high (Pdef) and a low (Pstr) load, representing serviceability limits for deflection and stress, respectively; both considerably higher than the maximum national wind load. The effect of a moderate axial load, as in loadbearing walls, was examined. The panels initially had a Degree of Composite Action (DCA) of 76-84%. The axially-loaded steel-reinforced panel achieved 1M cycles under Pstr, then another 1M under Pdef. Its DCA reduced to 73 then 65%. Without axial load, 1M and 0.24M cycles were achieved under Pstr and Pdef, and DCA reduced to 69 and 22%, respectively. The BFRP-panel failed at 0.07M cycles at Pstr. Its DCA reduced from 76 to 69%. It was then axially loaded and retested successfully to 1M cycles. Stiffness degradations of 12-50% consistent with DCA reductions were observed.

Description

Thesis (Master, Civil Engineering) -- Queen's University, 2015-09-26 02:20:19.714

Citation

Publisher

License

Queen's University's Thesis/Dissertation Non-Exclusive License for Deposit to QSpace and Library and Archives Canada
ProQuest PhD and Master's Theses International Dissemination Agreement
Intellectual Property Guidelines at Queen's University
Copying and Preserving Your Thesis
This publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.

Journal

Volume

Issue

PubMed ID

External DOI

ISSN

EISSN