Experimental setup and analysis method for the KDK ground state electron capture measurement of K-40

Loading...
Thumbnail Image

Authors

Stukel, Matthew

Date

Type

thesis

Language

eng

Keyword

MTAS , KDK , Potassium , Dark Matter , Geochronology

Research Projects

Organizational Units

Journal Issue

Alternative Title

Abstract

Potassium-40 is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, especially those involving NaI-based scintillators (ex. ANAIS-112, COSINE-100, COSINUS, DAMA/LIBRA, SABRE, etc.). The branching ratio of the electron capture directly to the ground state of Argon-40 has never been measured and presents an unknown background directly in the 2-6 keV energy region. This is the same region where the DAMA/LIBRA experiment observes their unique annual modulation. Knowledge of this branching ratio can place constraints on the allowed modulation fraction observed by the DAMA experiment. This branching ratio also has important implications for nuclear physics and geochronology. KDK (Potassium (K) Decay (DK)) is an international collaboration dedicated to the measurement of this branching ratio. This thesis details an experiment that is performed using a silicon drift detector with a thermally deposited, enriched K-40 source inside the Modular Total Absorption Spectrometer (MTAS, Oak Ridge National Laboratory). MTAS is a large NaI detector whose high gamma-ray efficiency enables the proper discrimination between ground and excited state electron capture events. Here we present the characterization of the KDK detector setup in terms of energy calibration, dead time, gamma tagging efficiency and false negatives and positives. The analysis of a blinded, 44-day experimental run is also shown. Finally, a comprehensive Monte Carlo program is developed for simulating the KDK experiment and evaluating its sensitivity. We find that the KDK experiment will allow a successful ground state branching ratio measurement, with a p-value greater than 10e-7, if the true value is greater than 0.1%.

Description

Citation

Publisher

License

Queen's University's Thesis/Dissertation Non-Exclusive License for Deposit to QSpace and Library and Archives Canada
ProQuest PhD and Master's Theses International Dissemination Agreement
Intellectual Property Guidelines at Queen's University
Copying and Preserving Your Thesis
This publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.
Attribution-NoDerivs 3.0 United States

Journal

Volume

Issue

PubMed ID

External DOI

ISSN

EISSN