Estimating Body Segment Inertial Parameters of the Human Body Using a Microsoft Kinect

Loading...
Thumbnail Image

Authors

Kudzia, Pawel

Date

2015-10-28

Type

thesis

Language

eng

Keyword

Body Segmentation , Microsoft Kinect V2 , Point Cloud , Body Volume , 3D Scanning , Biomechanics , 3D Mesh , Body Segment Inertial Parameters

Research Projects

Organizational Units

Journal Issue

Alternative Title

Abstract

Estimating biomechanical measures of the human body requires body segment inertial parameters (BSIP). Widely cited estimation methods (Chandler et al., 1975; Dempster, 1955) are based on an elderly population, have inherent errors (Hanavan, 1964) and may not represent subjects to which they are applied. Subject specific methods such as medical imaging or geometrical techniques can be time consuming, expensive and may require a variety of manually acquired inputs. Presented here is an alternative, subject specific approach to estimating BSIPs, requiring no manual measurements at a equipment cost of approximately $300. A 3D scanning protocol using a single Microsoft Kinect V2 was developed. Twenty-one subjects (10 male, 11 female) were scanned 3 times with per scan durations of approximately 20-30 seconds. Each full body 3D scan was segmented in Meshlab according to a 16 segment link model defined by Zatsiorsky and Seluyanov (1983). The 3D data was analyzed in custom MATLAB software that estimated the volume, MOI, COM, length and mass of each of the link segments. Results were compared to estimates obtained using an elliptical cylinder model (ECM) (Jensen 1978) and to estimates obtained using regression equations developed from medical imaging techniques (Zatsiorsky and Seluyanov 1983). The body volume estimates using the Kinect demonstrated high repeatability (ICC≥0.95) with a volume overestimation ranging from 0.0023 m3 (3%) for males and 0.0038m3 (5.1%) for females. The upper torso accounted for the majority of the overestimation of approximately 0.0019m3 (83%) for males and 0.002 m3 (53%) for the females. The Kinect protocol estimated COM with an average error of <2%. Segmental mass estimates were overestimated by 3.11% for males and 5.23% for females when compared to ECM. This research established that the Kinect V2 could be used as a tool for BSIP estimation. Future work should improve on the scanning posture, scanning protocol and reducing the scan duration. Furthermore, future research should investigate on methods to eliminate the manual segmentation proposed for this protocol.

Description

Thesis (Master, Mechanical and Materials Engineering) -- Queen's University, 2015-10-27 15:28:47.274

Citation

Publisher

License

Queen's University's Thesis/Dissertation Non-Exclusive License for Deposit to QSpace and Library and Archives Canada
ProQuest PhD and Master's Theses International Dissemination Agreement
Intellectual Property Guidelines at Queen's University
Copying and Preserving Your Thesis
Creative Commons - Attribution - CC BY
This publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.
This publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.
This publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.

Journal

Volume

Issue

PubMed ID

External DOI

ISSN

EISSN