A Fabry-Perot Refractometer for Chemical Vapor Sensing by Solid-Phase Microextraction

Loading...
Thumbnail Image

Authors

St-Gelais, R.
Mackey, G.
Saunders, J.
Zhou, J.
Leblanc-Hotte, A.
Poulin, A.
Barnes, Jack A.
Loock, Hans-Peter
Brown, Robert Stanley
Peter, Yves-Alain

Date

2016-03-14

Type

journal article

Language

en

Keyword

Chemical Sensors , Fabry-Perot , Microfluidics , Microoptics , Optical Sensors , Optical Device Fabrication

Research Projects

Organizational Units

Journal Issue

Alternative Title

Abstract

The contour lithography method [1] is used to improve the fabrication yield of previously demonstrated [2] microfluidic Fabry-Perot (FP) refractive index (RI) sensors. The sensors are then coated with polydimethylsiloxane (PDMS) based polymers to detect vapor analytes by solid-phase microextraction (SPME). Preliminary characterization of devices coated with two different polymers and exposed to xylenes vapors yields a maximum sensitivity of 0.015 nm/ppm and a detection limit below 120 ppm.